CS Installation Instructions This manual contains installation details for the CS control panels. It provides the basic programming and. CS Installation InstructionsThis manual contains installation details for the CS control panels. It provides the basic programming and inst. You can examine Aritech CS Manuals and User Guides in PDF. View online or download 1 Manuals for Aritech CS Besides, it’s possible to examine.

Author: Daimi Faerr
Country: Saudi Arabia
Language: English (Spanish)
Genre: Software
Published (Last): 12 December 2017
Pages: 326
PDF File Size: 19.6 Mb
ePub File Size: 19.78 Mb
ISBN: 285-9-67547-923-6
Downloads: 41985
Price: Free* [*Free Regsitration Required]
Uploader: Fenrisar

Zone Attributes Zone Type4. Aritech Corp assumes no responsibility for any errors which may appear in Documents.

When a panel mannual for [Call Engineer nn], were nn is a number, the user can’t arm his panel. If wiring is correct the bell should ring.

aritech cs manual Questions & Answers (with Pictures) – Fixya

Input values, program inertia Note that this also happens after returning to factory default. The load of the bells is greater than the fuse rating, inserting a higher value fuse may damage the panel. Disconnect bell wires from terminal and, observing correct polarity, connect across battery.

  HAIFISCHE IN DER SPREE PDF

Enter at Keypad 1 the default operators code [0][1][1][2][2]. Keyswitch arms panel without exit time.

Aritech CS350 Installation Instructions

See also Peridiax programming on p. Output as shown is ‘High’.

Bell cut off 30 min. If set to OFF then this output resets when the system is disarmed. Before installing the remote keypad RKP at it’s designated position, it may be connected at the control panel, to enable the engineer to commission the system. Arm system and remove wires from the terminal block. See page 21 for more details. The pulse count ismonitored after the first triggering in a window of 30s with 1s intervals.

Aritech CS Manuals

The keypad must be powerless when mqnual dipswitch settings. Option Operation No forced arming Forced arming is not possible. Enter ‘Show Open Zones’ in ‘Maintenance Menu’ and observe that the zone name in question does not come up on the display.

The [0] key has a blank space. The Display will prompt for the Language Default prefered.

  HARLAN KOBEN NIKOM NI RECI PDF

Triggering the input will activate the interior bell for 4 seconds,as well as latch and walk test outputs. During the entry procedure the entry timeris started which allows disarming. See also the chapter returning to factory default. The panel always powers up in Armed condition. Key Infinite creates an infinite exit time. Replace the plug-on link and reconnect the battery. Only after opening and closing this zone will the panel arm after four seconds.

Check that the battery fuse is not blown.

Only applicable for Alarm types. System does not activate when Tamper opens during day ie when system is disarmed. The input is automatically bypassed after an alarm till the second entry of a valid user code. If the system does not activate, disarm and enter Engineer Mode.